Information based on query as of Monday, July 1, 2024.
Permit Information
Permit NumberELE06-00193
StatusFinaled
Name ALLSTATE ELECTRIC INC
Site Address 502 N AVE E AVE
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - Alteration: wire for 110 volt hot tub, and install recessed can lighting in house
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final2/3/20062/3/20062/3/2006PPASS
DetailsPat Lass
andy --re-insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie
Final1/20/20061/23/20061/23/2006AFAIL
DetailsPat Lass
need inspection on hot tub and recessed can lighting. Call homeowner @###-#### to set time so she can be there to let you in Internet Inspection Request from: Andy
Rose
400.8 Uses Not Permitted.
Unless specifically permitted in 400.7, flexible cords and cables shall not be used for the following:
Cord not permitted for direct burial.
300.5 Underground Installations
(A) Minimum Cover Requirements Direct-buried cable or conduit or other raceways shall be installed to meet the minimum cover requirements of Table 300.5.
358.10 Uses Permitted
(B) Corrosion Protection Ferrous or nonferrous EMT, elbows, couplings, and fittings shall be permitted to be installed in concrete, in direct contact with the earth, or in areas subject to severe corrosive influences where protected by corrosion protection and judged suitable for the condition.
680.22 Area Lighting, Receptacles, and Equipment
(A) Receptacles
(2) Other Receptacles, Location Other receptacles shall be not less than 3.0 m (10 ft) from the inside walls of a pool.
(5) GFCI Protection All 15- and 20-ampere, single-phase, 125-volt receptacles located within 6.0 m (20 ft) of the inside walls of a pool shall be protected by a ground-fault circuit interrupter. Receptacles that supply pool pump motors and that are rated 15 or 20 amperes, 125 volts through 250 volts, single phase, shall be provided with GFCI protection.
680.8 Overhead Conductor Clearances
Overhead conductors shall meet the clearance requirements in this section. Where a minimum clearance from the water level is given, the measurement shall be taken from the maximum water level of the specified body of water.
Final1/18/20061/19/20061/19/2006ANH
DetailsPat Lass
110 volt hot tub and recessed can lighting in living room. Internet Inspection Request from: Andy Rose
no answer at the door called contractor to reschedual.