Permit NumberELE06-00214
StatusFinaled
Name A M E ELECTRIC
Site Address 10453 W K-BAR-T DR
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final5/25/20065/26/20065/26/2006APASS
DetailsJack Frank
jamie; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
Final5/15/20065/16/20065/16/2006AFAIL
DetailsJack Frank
Scheduled by a contractor via Hello! on 5/15/2006 at 6:35:28 PM. Contact: ###-####. corr. called shall provide manufactures access for j tub motor and recepts, install all closet shelves and rods, outlet right of fireplace no power, outside paddle fan is it listed for outside
Permanent Service2/2/20062/3/20062/3/2006APASS
DetailsJack Frank
Jamie -- for energizing service; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong p/s u/g new ok
Rough-In Permanent Service2/1/20062/2/20062/2/2006ACANC
DetailsMike Kinnear
Casey -- for ufer check; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong ---- home owner called for inspection. told he was not to call for inspections the electrical contractor has to so we know the work is ready for inspection.
Electrical Rough-In1/30/20061/30/20061/30/2006PPART
DetailsJack Frank
ufer ground inspection//casey ###-#### ok for dirt cover
Electrical Rough-In1/23/20061/24/20061/24/2006APASS
DetailsJack Frank
Scheduled by a contractor via Hello! on 1/23/2006 at 5:00:18 PM. Contact: ###-####. r/i ok
Electrical Rough-In1/23/20061/23/20061/23/2006AFAIL
DetailsJack Frank
electrode concrete cover ok only
cor. posted called 300.4 nail plates,11/4, 314.16 box fill, 314.17 replace damaged cutin and 2 gang boxes with broken out clamps,210.52(A&B) needs outlet left of oven wall space, wall between kit and liv rm shall be on kit circuit, 250.52(A)(1) grd u/g water 1st 5 ft, complete all makeup