Permit Information
Permit NumberELE06-00320
StatusFinaled
Name SHAW ROBERT R &
Site Address 6517 W MORTON DR
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/11/200712/11/200712/11/2007PPASS
DetailsBob Reichert
robert Phone #: ###-#### corrections made ok to final
Final12/10/200712/11/200712/11/2007AFAIL
DetailsJack Frank
Robert Please call 30 min before going out Phone #: ###-#### corr not made
Final12/6/200712/7/200712/7/2007AFAIL
DetailsBob Reichert
robert Note: please call 1/2 hr prior to be open Phone #: ###-#### met owner, left correction notice, nec 406.8(B) outdoor receptacles shall have weatherproof covers installed whether or not cord is in use, 210.12(B) dwelling unit bedrooms shall be protected by arc fault circuit interrupters, 410.8(B) closet fixtures shall have completely enclosed lamp, 410.8(D) closet fixtures shall be 12" from edge of shelves for incandescent and 6" for fluorescent
Electrical Rough-In2/14/20072/15/20072/15/2007ACANC
DetailsBob Reichert
robert; Phone #: ###-#### Internet Inspection Request from: Victoria Beall wrong type insp, see rip
Rough-In Permanent Service2/15/20072/15/20072/15/2007ACANC
DetailsBob Reichert
robert; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr made, told owner to get room count on permit correct-19 rooms, ric ok, p/s u/g n ok
Electrical Rough-In1/30/20071/30/20071/30/2007PFAIL
DetailsBob Reichert
robert; Phone #: ###-#### Internet Inspection Request from: Darla Downs met owner, left corr notice, nec 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing members, 314.20 boxes shall be flush with finished surface, 314.17(C) nm cable shall be stapled within 8" of box, NOTE: upgrade permit to 19 rooms