Final | 3/12/2006 | 3/13/2006 | 3/13/2006 | P | PASS |
William E Thomas
|
|
|
Scheduled by a contractor via Hello! on 3/12/2006 at 8:52:06 PM. Contact: ###-####.
|
Final | 3/8/2006 | 3/8/2006 | 3/8/2006 | P | FAIL |
Bob Reichert
|
|
|
Chuck; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong called contr, left corr notice, 408.4 circuit directory shall be complete, clear, and provide detail for purpose, 406.4 receptacles shall be securely mounted and fastened in place, 334.30 nm cable shall be secured within 12" of box(out of panel), 406.8(B) outside gfci receptacle shall have cover that is weatherproof whether or not attachment plug cap is inserted.
|
Electrical Rough-In | 2/2/2006 | 2/3/2006 | 2/3/2006 | A | PASS |
Bob Reichert
|
|
|
Neil ###-#### ric ok
|