Final | 3/10/2006 | 3/13/2006 | 3/13/2006 | A | PASS |
Pat Lass
|
|
|
Corrections have been completed. Thanks!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell P/S O/H R Ok
|
Final | 2/22/2006 | 2/27/2006 | 2/27/2006 | A | FAIL |
Pat Lass
|
|
|
We upgraded the service to 200 amps, drove 2 ground rods,(waterpipe was plastic feeding house), replaced 2 existing garage fuse boxes with a new 200 amp panel and fed it with a 200 amp 4 wire circuit from the outside service.(#6020125isla). Thanks!!! Dan.; Phone #: ###-#### Internet Inspection Request from: Dan Mitchell
250.104 Bonding of Piping Systems and Exposed Structural Steel. (1) must go to the service. (A) Metal Water Piping.
310.15 Ampacities for Conductors Rated 0-2000 Volts. Service conductors are only #2 al
250.140 Frames of Ranges and Clothes Dryers. the branch circuit originates at the service equipment.
314.28 Pull and Junction Boxes and Conduit Bodies. LB is listed for 3 3/0 only
|