Information based on query as of Wednesday, July 17, 2024.
Permit Information
Permit NumberELE06-00735
StatusFinaled
Name BOISE ELECTRIC
Site Address 4802 W KOOTENAI ST
Project NameRIVER CITY REAL ESTATE
Customer Number 
ePlanReview 
Description
3/2/2006 - existing residential changed to office - $12,000.00 per initial cert of value - cmc ///Final cert of value is $12,000//1/4/07 LEG
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/15/20069/15/20069/15/2006PPASS
DetailsJack Frank
glen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok card signed
Final9/14/20069/15/20069/15/2006ANR
DetailsJack Frank
glen; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
Permanent Service3/20/20063/21/20063/20/2006APASS
DetailsJack Frank
Glen; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong
p/s u/g new ok
Rough-In Permanent Service3/6/20063/7/20063/7/2006APART
DetailsJack Frank
glen; Phone #: ###-#### Internet Inspection Request from: Letitia Mesa no p/s , r/i ok lectrode ok for cover needs to seal KOs remove Sq D breaker install cover at subpanel called
Rough-In Permanent Service3/3/20063/3/20063/3/2006PNR
DetailsJack Frank
Glen -- reinspection; Phone #: ###-#### Internet Inspection Request from: Elizabeth Esong all corr. not made and wiring not complete met contractor
Electrical Rough-In3/2/20063/2/20063/2/2006PFAIL
DetailsBob Reichert
###-#### - Note: RI and grounding ring met elect, left corr notice,300.4(A)&(D) edges of holes and edge of mc cable shall be 1 1/4" from edge of framing member, 312.5 all conductors entering enclosures shall have abrasion protection, 210.63 recpt shall be within 25 ft of a/c equipment, 330.30(B) mc cable shall be fastened within 12 " of box,314.23(B)(1) nails and screws used to fasten box shall use brackets on the outside of box or pass thru the interior within 1/4" of the back or ends of the enclosure, 800.133(A)(1) communications cables shall not be run in raceway with electric, light, power circuits,BCC all make-up shall be done. ok to pour gec. call before backfill Wrote correction notice to bld05-01394-BCC low voltage wiring shall be installed by licensed lv contractor