Final | 7/21/2006 | 7/24/2006 | 7/24/2006 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/21/2006 at 2:30:23 PM. Contact: ###-####. ok to final
|
Permanent Service | 5/3/2006 | 5/3/2006 | 5/3/2006 | P | PASS |
Bob Reichert
|
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman p/s u/g n ok
|
Electrical Rough-In | 5/3/2006 | 5/3/2006 | 5/3/2006 | P | PASS |
Bob Reichert
|
|
|
re-inspect - Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman corr made, ric ok
|
Electrical Rough-In | 5/2/2006 | 5/3/2006 | 5/3/2006 | A | FAIL |
Bob Reichert
|
|
|
Rick; Phone #: ###-#### Internet Inspection Request from: Ione Coleman called contr, left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 314.16 boxes shall be of sufficient size to provide free space for all enclosed conductors (garage lites)
|