Final | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | PASS |
Pat Lass
|
|
|
Internet Inspection Request from: Steve Craig
|
Final | 10/5/2006 | 10/6/2006 | 10/6/2006 | P | CANC |
Pat Lass
|
|
|
Internet Inspection Request from: Steve Craig
|
Final | 10/5/2006 | 10/6/2006 | 10/6/2006 | A | FAIL |
Pat Lass
|
|
|
Internet Inspection Request from: Steve Craig island counter recep above counter and protect romex in microwave space \GFCI recep within 6 ft of laundry sink secure box on hydronic system secure permit for outside lighting
|
Permanent Service | 9/21/2006 | 9/22/2006 | 9/22/2006 | A | PASS |
Pat Lass
|
|
|
Call Steve at ###-#### if there are any questions. Internet Inspection Request from: Steve Craig P/S U/G N Ok
|
Electrical Rough-In | 6/29/2006 | 6/30/2006 | 6/30/2006 | A | PASS |
Jim Schmer
|
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley
|
Conference | 6/27/2006 | 6/27/2006 | 6/27/2006 | P | DONE |
Jack Frank
|
|
|
steve; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called contractor had ? on bonding building steel answered ? told him when installed call for inspection
|
Electrical Rough-In | 6/26/2006 | 6/26/2006 | 6/26/2006 | P | NR |
Pat Lass
|
|
|
steve - not the perm service; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley bond all building steel together with #4 wire. install plastic mud ring on blue carlon box by the stairs install "J" box to get 1 in. flex to under 360 deg. of bend
|