Electrical Rough-In | 1/11/2007 | 1/11/2007 | 1/11/2007 | P | PASS |
Bob Reichert
|
|
|
ron - please call 1/2 hr prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr made, ric ok
|
Electrical Rough-In | 1/9/2007 | 1/9/2007 | 1/9/2007 | P | NH |
Jack Frank
|
|
|
ron ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith called left message no response
|
Electrical Rough-In | 1/2/2007 | 1/2/2007 | 1/2/2007 | P | FAIL |
Jack Frank
|
|
|
ron - please call 1/2 hr prior to inspection ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith corr. not made 400.14 short grd wires, 300.4 nail plates, cables stapled on edge, conn for GEC
|
Electrical Rough-In | 10/23/2006 | 10/23/2006 | 10/23/2006 | P | CANC |
Jim Schmer
|
|
|
ron - call 1st before insp ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie was a conference only to explain corrections jms
|
Rough-In Permanent Service | 7/18/2006 | 7/18/2006 | 7/18/2006 | P | FAIL |
Bob Reichert
|
|
|
ron -call 1st for access ; Phone #: ###-#### Internet Inspection Request from: Marsha Smylie--re-insp told people at house, left corr notice,nec 334.30 nm cable shall be stapled within 12" of box, nm cable shall not be stapled on edge, 300.4(A)&(D) edge of holes and nm cable shall be 1 1/4" from edge of framing member, 314.20 in walls of combustible material box shall be flush with finished surface, 300.14 at least 6" of free conductor length shall emerge at each box 352.30 rnc shall be supported within 3' of box, BCC all make-up shall be done, all underground shall be inspected before cover
|
Rough-In Permanent Service | 7/17/2006 | 7/18/2006 | 7/18/2006 | A | NH |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/17/2006 at 7:25:42 PM. called, left message, tried door, left card
|