Final | 6/21/2007 | 6/22/2007 | 6/22/2007 | A | PASS |
Pat Lass
|
|
|
Phone #: ###-####
|
Final | 6/21/2007 | 6/21/2007 | 6/21/2007 | P | FAIL |
Pat Lass
|
|
|
dave or roger ###-#### Phone #: ###-#### 410.8(B) shall provide globe guard for closet light, BCC disposal shall be wired, room count on permit shall be at least 12 rooms
|
Final | 6/14/2007 | 6/14/2007 | 6/14/2007 | P | FAIL |
Bob Reichert
|
|
|
dave ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith told contr, he called for inspection, left corr notice, 406.5 recpt faceplates shall seat against mounting surface, 406.4(D) recpt faces shall be flush with or project from faceplate,406.4 recpts shall be securely fastened in place(laundry), 408.4 circuit directory shall be clear, concise, and explanatory for each circuit and purpose, 210.52(A)(2) 2' wall space shall have recpt behind shower, 110.3(B) listed equip shall be installed per mfgr's instructions(no reverse polarity), 410.8(B) shall provide globe guard for closet light, BCC disposal shall be wired, room count on permit shall be at least 12 rooms
|
Electrical Rough-In | 1/5/2007 | 1/8/2007 | 1/8/2007 | A | PASS |
Pat Lass
|
|
|
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles
|
Permanent Service | 10/2/2006 | 10/3/2006 | 10/3/2006 | A | PASS |
Pat Lass
|
|
|
###-#### P/S U/G N Ok
|
Electrical Rough-In | 9/29/2006 | 10/2/2006 | 10/2/2006 | A | PART |
Pat Lass
|
|
|
roger; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley electrode ok for concrete after footing is cleaned off.
|
Permanent Service | 9/21/2006 | 9/21/2006 | 9/21/2006 | P | FAIL |
Pat Lass
|
|
|
roger ; Phone #: ###-#### Internet Inspection Request from: Barbara Buckley concrete encased electrode required because the re-bar is only 3/8"
|