Permit Information
Permit NumberELE06-03281
StatusFinaled
Name FRAHLER ELECTRIC CO
Site Address 5850 N FIVE MILE RD
Project NameBONAVENTURE PLACE
Customer Number63338
ePlanReview 
Description
bldg line voltage, bldg low voltage- lights, plugs, all connections and electrical service per initial cert of value $834,000.00
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final8/30/20078/31/20078/31/2007APASS
DetailsJack Frank
Please inspect final for A and B wings. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok card signed
Final8/29/20078/30/20078/30/2007PCANC
DetailsJack Frank
Please inspect for final in A and B wings. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend Inspection cancelled from web by: Jim Friend
Final8/23/20078/24/20078/24/2007PPART
DetailsJack Frank
Please inspect for final at both A and B wings. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Frit/od
t/o ok card signed
Final8/21/20078/22/20078/22/2007APART
DetailsJack Frank
Please inspect for final 3rd floor B-wing and all floors A-wing. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok
Final8/16/20078/16/20078/16/2007APART
DetailsJack Frank
final D wing 3rd floor ok needs to address max o/c protection for a/c units 15,20,30, amps? met with Jim Friend
Electrical Rough-In8/15/20078/16/20078/16/2007ACANC
DetailsJack Frank
Please inspect kitchen rough-in (B-wing). Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend see added final
Electrical Rough-In8/7/20078/8/20078/8/2007APART
DetailsJack Frank
Please inspect ceiling rough-in cover in B-wing. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend
ok 1st 2nd floors
Final7/9/20077/10/20077/10/2007APART
DetailsJack Frank
Please inspect final for A-wing. Thanks. Phone #: ###-#### Internet Inspection Request from: Jim Friend rms ok still need to check closets after shelves are installed for clearence
Final7/2/20077/2/20077/2/2007PCANC
DetailsJack Frank
Please inspect 1st and 2nd floor of A-wing ceiling cover. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend called already done on added r/i 06-29-07
Final6/28/20076/29/20076/29/2007ACANC
DetailsJack Frank
Please inspect 1st and 2nd floor of A-wing ceiling cover. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend see added r/i
Electrical Rough-In6/20/20076/21/20076/21/2007APASS
DetailsJack Frank
Please inspect 1st and 2nd floor of B-wing rough-in. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend anop
Electrical Rough-In6/1/20076/4/20076/4/2007APART
DetailsJack Frank
Please inspect 3rd floor B-wing rough-in. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok anop, also looked at genset needs bond bushings
Electrical Rough-In5/29/20075/30/20075/30/2007APASS
DetailsJack Frank
Please inspect A-wing panels. Thank you. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok
Electrical Rough-In4/23/20074/24/20074/24/2007APART
DetailsJack Frank
Please inspect kitchen in commons (B-wing). Thankyou. Phone #: ###-#### Internet Inspection Request from: Jim Friend ok anop
Electrical Rough-In3/23/20073/26/20073/26/2007APART
DetailsJack Frank
Please inspect 3rd floor rough-in at A-wing. Thankyou. Phone #: ###-####
walls ceilings ok anop
Electrical Rough-In3/8/20073/9/20073/9/2007APART
DetailsJack Frank
Please inspect rough-in at 2nd floor of A-wing. Thank you. Phone #: ###-####
ok anop
Electrical Rough-In3/5/20073/6/20073/6/2007APART
DetailsJack Frank
Please inspect 1st floor rough-in at A-wing. Thankyou. Phone #: ###-#### ok anop
Electrical Rough-In3/2/20073/5/20073/5/2007AFAIL
DetailsJack Frank
Please inspect 1st floor rough-in at A-wing. Thankyou. Phone #: ###-#### met contr not ready outlet spacing, and remove duct tape from flex at panel 300.10 elect. continunity
Electrical Rough-In3/1/20073/2/20073/2/2007PCANC
DetailsJack Frank
Please inspect 1st floor of A-wing rough-in. Thankyou. Phone #: ###-#### Inspection cancelled from web by: Jim Friend
Electrical Rough-In1/9/20071/9/20071/9/2007PPART
DetailsJack Frank
Please inspect underslab conduits at MDP room this morning if possible. Please see Dale at trailer for inspection location. Thanks! Phone #: ###-####
u/g ok main service area
Electrical Rough-In10/12/200610/13/200610/13/2006APART
DetailsBob Reichert
Please inspect B-wing underground early in AM if possible. Thanks!; Phone #: ###-#### Internet Inspection Request from: Jim Friend B-wing u/g under slab ok to cover anop
Electrical Rough-In10/11/200610/12/200610/12/2006APART
DetailsBob Reichert
Please inspect B-wing underground in AM.; Phone #: ###-#### Internet Inspection Request from: Jim Friend B wing u/g anop ok to cover
Electrical Rough-In9/20/20069/21/20069/21/2006PPART
DetailsBob Reichert
Please inspect partial underground of A-wing around 2:30 if possible.; Phone #: ###-#### Internet Inspection Request from: Jim Friend ok to cover partial e-w u/g at A-wing
Electrical Rough-In9/18/20069/19/20069/19/2006APART
DetailsBob Reichert
Please inspect partial underground for B-wing. Thanks.; Phone #: ###-#### Internet Inspection Request from: Jim Friend oki for part u/g anop for B-wing
Electrical Rough-In9/14/20069/15/20069/15/2006PCANC
DetailsBob Reichert
Please inspect partial B-wing underground in PM. Thanks; Phone #: ###-#### Internet Inspection Request from: Jim Friend Inspection cancelled from web by: Jim Friend
Electrical Rough-In9/13/20069/14/20069/14/2006PPART
DetailsBob Reichert
Please inspect partial underground for A/B wing around 2:30 if possible. Thanks!; Phone #: ###-#### Internet Inspection Request from: Jim Friend u/g for unit a only ok to cover up to bldg line on north side bldg