Final | 12/7/2006 | 12/7/2006 | 12/7/2006 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 12/7/2006 at 9:13:35 AM. Contact: ###-####. ok to final, called to id disconnects
|
Final | 12/6/2006 | 12/7/2006 | 12/7/2006 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 12/6/2006 at 2:12:43 PM. Contact: ###-####. no access called
|
Permanent Service | 10/20/2006 | 10/20/2006 | 10/20/2006 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson corr made, p/s u/g n ok
|
Permanent Service | 10/9/2006 | 10/10/2006 | 10/10/2006 | A | NR |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/9/2006 at 1:43:04 PM. Contact: ###-####. grounding not complete, needs bushings for #4 and larger
|
Electrical Rough-In | 10/10/2006 | 10/10/2006 | 10/10/2006 | A | PART |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/9/2006 at 1:43:04 PM. Contact: ###-####. electrode ok for concrete cover
|
Permanent Service | 10/5/2006 | 10/5/2006 | 10/5/2006 | P | CANC |
Bob Reichert
|
|
|
thank you!; Phone #: ###-#### Internet Inspection Request from: Zane Robertson called contr, wrong type inspection request, see ri
|
Electrical Rough-In | 10/5/2006 | 10/5/2006 | 10/5/2006 | P | FAIL |
Bob Reichert
|
|
|
thank you!; Phone #: ###-#### Internet Inspection Request from: Zane Robertson called contr, said to clean out around gec and recall for inspection to pour, said that 4" conduit into 4" deep can would not work because cutting down locknut voids ul listing and that bushing will not fit either. Told about either ground both disconnects or locate in meter can.
|
Rough-In Permanent Service | 10/2/2006 | 10/3/2006 | 10/3/2006 | A | PART |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Zane Robertson r/i ok
|
Conference | 9/5/2006 | 9/6/2006 | 9/6/2006 | A | CANC |
Mike Kinnear
|
|
|
please do underground inspection only. thanks; Phone #: ###-#### Internet Inspection Request from: Zane Robertson wrong type inspection
|
Electrical Rough-In | 9/6/2006 | 9/6/2006 | 9/6/2006 | A | PASS |
Mike Kinnear
|
|
|
please do underground inspection only. thanks; Phone #: ###-#### Internet Inspection Request from: Zane Robertson ok cover under slab conduit & boxes
|