DOC - Permit Finaled | 1/25/2007 | 1/25/2007 | 1/25/2007 | P | PASS |
Jack Frank
|
|
|
owner's permited voided, contr doing work now on ele07-00218
|
Electrical Rough-In | 1/11/2007 | 1/12/2007 | 1/12/2007 | A | FAIL |
Mike Kinnear
|
|
|
senad; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles correction not done told owner he had to get an electrical contractor to do the work & we would have to void his permit. he said he would get an electrical contractor. note we need to void this permit when new contractor gets permit
|
Electrical Rough-In | 12/14/2006 | 12/14/2006 | 12/14/2006 | P | FAIL |
Jack Frank
|
|
|
Sanad Note: Call 1/2 before insp; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett met owner, prior violations not made and new ones created, cut wires too short, used screws in plastic boxes, boxes shall be flush with siding, see corr, notes for prior inspection staple all cables within 8" of boxes
|
Final | 12/13/2006 | 12/13/2006 | 12/13/2006 | P | NH |
Jack Frank
|
|
|
Senad; Phone #: ###-#### Internet Inspection Request from: Sherri Bennett
notice posted called talked with owner he will reschedule for am also r/i not final
|
Electrical Rough-In | 11/17/2006 | 11/17/2006 | 11/17/2006 | P | FAIL |
Jack Frank
|
|
|
###-#### corr. met owner, 300.4(A)(1)&(D) nail plates and 11/4" for holes and cables, 314.20 outside boxes shall be flush with siding, 210.52(A) outlet fixed panel of sliding door wall space, 110.3(B) wire jtub per manufactures instructions, 210.11(C)(3)&52(D) 20 amp bath circuit and location for outlet bathrm, strip sheath from romex and makeup of boxes 6" free lenght, staple cables within 8" ok boxes
|
Electrical Rough-In | 11/16/2006 | 11/17/2006 | 11/17/2006 | A | FAIL |
Jack Frank
|
|
|
after 9am please//Billie ###-#### metr owner will post correction
|
Electrical Rough-In | 11/7/2006 | 11/8/2006 | 11/8/2006 | A | FAIL |
Bob Reichert
|
|
|
Billie ###-####//requests around 9am showed owner make-up, 1 1/4", add recpt in bathroom
|
Electrical Rough-In | 11/7/2006 | 11/7/2006 | 11/7/2006 | P | NH |
Bob Reichert
|
|
|
Billie ###-####//requests either early pm or late pm because she has to pick up kids at 2:30 called, owner not living there, could not be there for a while, inspector said to request another inspection when owner available, such as in morning
|
Conference | 10/10/2006 | 10/11/2006 | 10/11/2006 | A | DONE |
Bob Reichert
|
|
|
Senad ###-####//please call 30 min prior to meet no work done, adding some repts, will call ltr
|