Final | 11/21/2006 | 11/21/2006 | 11/21/2006 | P | PASS |
Bob Reichert
|
|
|
BOB; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr made, ok to final
|
Final | 11/20/2006 | 11/21/2006 | 11/21/2006 | A | FAIL |
Bob Reichert
|
|
|
dan ; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called ,left corr notice, 404.9 shall provide faceplates for switch, 410.30.(C)(1) recpt shall be directly over fixture, 422.30 shall provide disc for water heater, 250.104 shall bond hot and cold water pipe, 110.3(B) gfci shall be installed per instruction
|
Permanent Service | 11/7/2006 | 11/8/2006 | 11/8/2006 | A | PASS |
Mike Kinnear
|
|
|
brian; Phone #: ###-#### Internet Inspection Request from: Patricia Smith p/s u/g n ok
|
Electrical Rough-In | 11/3/2006 | 11/3/2006 | 11/3/2006 | P | PASS |
Bob Reichert
|
|
|
dan - Note: ok to cover walls; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles walls only ok to cover
|