Final | 11/8/2007 | 11/9/2007 | 11/9/2007 | A | PASS |
Bob Reichert
|
|
|
Shane Phone #: ###-#### corrections made, ok to final
|
Final | 11/7/2007 | 11/8/2007 | 11/8/2007 | A | FAIL |
Bob Reichert
|
|
|
Please call for access information--shane; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt called contractor, left correction notice, nec 210.70(A)(3) shall provide lighting outlet in basement room with equipment requiring servicing, 210.52(B)(2) shall not have outside rear receptacle on small appliance branch circuit, 110.12(A) shall close unused opening in a/c disconnect, 406.4 kitchen recpt shall be securely mounted, 422.31(B) shall provide disconnect with lockout for water heater
|
Electrical Rough-In | 3/19/2007 | 3/20/2007 | 3/20/2007 | A | PASS |
Pat Lass
|
|
|
shane ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith
|