Permit Information
Permit NumberELE07-00053
StatusFinaled
Name BETTER HOMES ELECTRIC
Site Address 3308 W LEMHI ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final4/20/20074/20/20074/20/2007APASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 4/20/2007 at 6:49:05 AM. Contact: ###-####. called contr to tighten 2 recpts, ok to final
Electrical Rough-In1/9/20071/9/20071/9/2007PPASS
DetailsWilliam E Thomas
roger; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
1. ri ok
Rough-In Permanent Service1/5/20071/8/20071/8/2007ACANC
DetailsBob Reichert
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles see p/s and ri
Electrical Rough-In1/8/20071/8/20071/8/2007AFAIL
DetailsBob Reichert
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles called left corr notice, nec 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing member or protected by steel plate,314.20 box shall be flush with finished surface , rear light, 334.30 nm cable shall not be stapled on edge
Permanent Service1/8/20071/8/20071/8/2007APASS
DetailsBob Reichert
roger; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles p/s o/h n ok