Final | 5/2/2007 | 5/2/2007 | 5/2/2007 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 5/2/2007 at 9:26:01 AM. Contact: ###-####. corr made house ok
|
Final | 4/26/2007 | 4/26/2007 | 4/26/2007 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 4/26/2007 at 10:33:22 AM. Contact: ###-####. corr called 314,3 shall remove metallic race from plastic box island
|
Electrical Rough-In | 4/6/2007 | 4/6/2007 | 4/6/2007 | P | PASS |
Bob Reichert
|
|
|
zane - inspect the floor heat; Phone #: ###-#### Internet Inspection Request from: Victoria Beall ok to cover for floor heat
|
Rough-In Permanent Service | 2/7/2007 | 2/7/2007 | 2/7/2007 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/7/2007 at 11:06:30 AM. Contact: ###-####. r/i ok corrections made
|
Rough-In Permanent Service | 2/6/2007 | 2/7/2007 | 2/7/2007 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/6/2007 at 3:52:19 PM. Contact: ###-####. corr. not made still needs to add outlet for wall space fee due called
|
Rough-In Permanent Service | 2/2/2007 | 2/5/2007 | 2/5/2007 | A | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/2/2007 at 12:38:33 PM. Contact: ###-####. corr. called 300.4 nail plates, 210.52(A) outlets required stair wall kit. din., liv. rm wall by entry, 250.122 needs #12 equip grd wire kit, where 12&14 are in same box, corr for low voltage. bld06-02488 300.4(A)(1)&(D) nail plates and 11/4" for cables parallel to framing members
|