Final | 2/6/2007 | 2/7/2007 | 2/7/2007 | A | PASS |
Jack Frank
|
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles ok
|
Electrical Rough-In | 2/6/2007 | 2/7/2007 | 2/7/2007 | A | PASS |
Jack Frank
|
|
|
darrell; Phone #: ###-#### Internet Inspection Request from: Cathy ok
|
Final | 2/5/2007 | 2/5/2007 | 2/5/2007 | P | NR |
Jack Frank
|
|
|
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
|
Electrical Rough-In | 2/5/2007 | 2/5/2007 | 2/5/2007 | P | FAIL |
Jack Frank
|
|
|
daryl; Phone #: ###-#### Internet Inspection Request from: Victoria Beall corr. called 210.52(A) shall prvide reqired outlets for spacing, 314.16 correct all box fill, 300.10&12 shall maintain elect. and mech. continunity of raceways flex from box to wall heater and wiremold, 386.2, 21, 100 shall use listed fittings for wiremold, shall not run romex in wiremold, provide abrasion protection
|