Permit Information
Permit NumberELE07-00512
StatusFinaled
Name TREASURE VALLEY ELECTRIC INC
Site Address 2023 E TABLE ROCK RD
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - Addition: Remodel of existing house. Upgrade to 400 amp service.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final7/31/20078/1/20078/1/2007APASS
DetailsWilliam E Thomas
Phone #: ###-#### Internet Inspection Request from: Steve Craig
final ok
Final7/31/20077/31/20077/31/2007PFAIL
DetailsJack Frank
Phone #: ###-#### Internet Inspection Request from: Steve Craig corr called left message, 210.8 (1) all recepts in bath rms shall have gfci
Final7/26/20077/27/20077/27/2007PNR
DetailsPat Lass
Phone #: ###-#### Internet Inspection Request from: Steve Craig
This inspection is incomplete because not everything was working.

For a final inspection in the city of Boise all of the electrical must be complete and in working order. This includes the installation of lamps in all lighting fixtures.

210.8 Ground-Fault Circuit-Interrupter Protection for Personnel.
(A) Dwelling Units. All 125-volt, single-phase, 15- and 20-ampere receptacles installed in the locations specified in (1) through (8) shall have ground-fault circuit-interrupter protection for personnel.
(1) Bathrooms
(7) Laundry, utility, and wet bar sinks - where the receptacles are installed within 1.8 m (6 ft) of the outside edge of the sink
Electrical Rough-In5/9/20075/10/20075/10/2007APASS
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Steve Craig ok to cover rest of floor heat
Electrical Rough-In5/9/20075/9/20075/9/2007PPART
DetailsJack Frank
steve; Phone #: ###-#### Internet Inspection Request from: Victoria Beall
partial for elect floor heat about 1/2 of floor heat installed
Electrical Rough-In3/30/20074/2/20074/2/2007APASS
DetailsPat Lass
Phone #: ###-####
Electrical Rough-In3/29/20073/30/20073/30/2007AFAIL
DetailsPat Lass
Phone #: ###-####
corrections not made
Electrical Rough-In3/28/20073/29/20073/29/2007PFAIL
DetailsPat Lass
Request for rough-in inspection Phone #: ###-####
250.148 Continuity and Attachment of Equipment Grounding Conductors to Boxes.
(A) Metal Boxes. A connection shall be made between the one or more equipment grounding conductors and a metal box
300.14 Length of Free Conductors at Outlets, Junctions, and Switch Points.
314.16 Number of Conductors in Outlet, Device, and Junction Boxes, and Conduit Bodies.
Boxes and conduit bodies shall be of sufficient size to provide free space for all enclosed conductors.
300.4 Protection Against Physical Damage.
Where subject to physical damage, conductors shall be adequately protected.
(D) Cables and Raceways Parallel to Framing Members.

334.30 Securing and Supporting.
Nonmetallic-sheathed cable shall be secured by staples, cable ties, straps, hangers, or similar fittings designed and installed so as not to damage the cable at intervals not exceeding 1.4 m (41/2 ft) and within 300 mm (12 in.) of every cabinet, box, or fitting. Flat cables shall not be stapled on edge.
110.12 Mechanical Execution of Work.
Electrical equipment shall be installed in a neat and workmanlike manner.
(A) Unused Openings. Unused cable or raceway openings in boxes, raceways, auxiliary gutters, cabinets, cutout boxes, meter socket enclosures, equipment cases, or housings shall be effectively closed
Permanent Service2/14/20072/15/20072/15/2007APASS
DetailsMike Kinnear
Phone #: ###-#### p/s u/g n ok
Rough-In Permanent Service2/13/20072/14/20072/14/2007PNR
DetailsMike Kinnear
Service change scheduled with Idaho Power for 8:00 a.m. Inspection in afternoon for reconnect. Phone #: ###-#### conf with electrician nec250.64(C) & metal water service. they to fix & recall for inspection. no ri ready yet