Permit Information
Permit NumberELE07-00558
StatusFinaled
Name ERIC ANDERSON
Site Address 1617 N 21ST ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/3/20083/3/20083/3/2008PPASS
DetailsPat Lass
eric Phone #: ###-####
Final12/28/200712/28/200712/28/2007PFAIL
DetailsBob Reichert
eric Phone #: ###-#### met owner, left correction notice, nec 210.12(B) bedrooms shall have afci protection installed, 406.8(A) garage outdoor recptacle shall have in-use cover installed, asked owner to strap conduit that was existing in garage, everything else in house inspected, told could move in, but we have to inspect afci and owner must provide room for access
Conference12/27/200712/27/200712/28/2007PDONE
DetailsBob Reichert
eric Phone #: ###-#### met owner , talked about in-use covers, strapping risers, bond screw, outside gfci, kitchen gfci, dead receptacles, open neutrals, open grounds, closet lights, abandon wire not used, flush switch plates, heater disconnect,flex over nm cable, staple nm cable at heater area, finish install lights, switches, dead receptacles, afci for bedrooms, if move in, allow 3' clear space around walls for inspection, owner made list of items
Final12/26/200712/27/200712/27/2007PCANC
DetailsBob Reichert
eric Phone #: ###-#### see conference
Electrical Rough-In9/20/20079/20/20079/20/2007PPASS
DetailsPat Lass
eric Phone #: ###-####
Electrical Rough-In9/17/20079/17/20079/17/2007PNR
DetailsPat Lass
eric Note: cover up Phone #: ###-####
had conf with homeowner.
many violations existed no make up was done
Electrical Rough-In7/10/20077/10/20077/10/2007PPART
DetailsPat Lass
eric - cover; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang
under floor ok
Electrical Rough-In7/9/20077/9/20077/9/2007PNR
DetailsPat Lass
eric Phone #: ###-####
junction box shall not be burried
Electrical Rough-In4/2/20074/3/20074/3/2007PCANC
DetailsWilliam E Thomas
eric Please call first before going out; Phone #: ###-#### Internet Inspection Request from: Darla Downs
wrong type inspection
Conference4/3/20074/3/20074/3/2007PDONE
DetailsWilliam E Thomas
eric Please call first before going out; Phone #: ###-#### Internet Inspection Request from: Darla Downs
answered questions about his basement and what was required as far as spacing between outlets.
Permanent Service4/3/20074/3/20074/3/2007PPASS
DetailsWilliam E Thomas
eric Please call first before going out; Phone #: ###-#### Internet Inspection Request from: Darla Downs
p/s o/h reconnect ok
Conference2/23/20072/23/20072/23/2007PCANC
DetailsPat Lass
Eric, after 2:30 today please; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt
had conf about total rewire
Conference2/20/20072/20/20072/20/2007PCANC
DetailsPat Lass
eric; Phone #: ###-#### Internet Inspection Request from: Victoria Beall