Final | 8/29/2007 | 8/30/2007 | 8/30/2007 | A | PASS |
Jack Frank
|
|
|
this permit should have been finaled out back in March when the corrections were made and reinspection was called in race way to track portion of lights were installed Phone #: ###-#### Internet Inspection Request from: Brad Baker
|
Final | 3/22/2007 | 3/22/2007 | 3/22/2007 | P | PART |
Jack Frank
|
|
|
lock box on light pole out front access code 4584 everthing should be ready for you thanks Brad Phone #: ###-#### t/o ok survey posted track shall not be fed with cord 410.101(A), 110.3(B) follow manufactures instructions
|
Final | 3/21/2007 | 3/21/2007 | 3/21/2007 | P | FAIL |
Bob Reichert
|
|
|
lock box on pole light in front code 4584 for front door key thank you Phone #: ###-#### called, left corr notice, nec 408.4 circuit directory shall be clear concise and accurate for its purpose, each circuit, 358.39 emt shall be strapped within 3' of it's termination, 406.4 recpt shall be securely fastened in place, BCC fixtures shall have independent support wires
|
Electrical Rough-In | 2/23/2007 | 2/26/2007 | 2/26/2007 | A | PASS |
Bob Reichert
|
|
|
everthing should be ready now please call first for access Phone #: ###-#### corr made, walls only ok to cover
|
Conference | 2/23/2007 | 2/23/2007 | 2/23/2007 | P | CANC |
Bob Reichert
|
|
|
Brad; Phone #: ###-####, call 1st for access Internet Inspection Request from: Cathy Weisshaupt see ri, wrong type request,
|
Electrical Rough-In | 2/23/2007 | 2/23/2007 | 2/23/2007 | P | FAIL |
Bob Reichert
|
|
|
Brad; Phone #: ###-####, call 1st for access Internet Inspection Request from: Cathy Weisshaupt called, left message, nec 300.4(D) edge of mc cable shall be 1 1/4" from edge of framing member, no mc in valley of 2x4 stud
|