Permit Information
Permit NumberELE07-01280
StatusFinaled
Name JR ELECTRIC
Site Address 6502 W POPLAR ST
Project Name 
Customer Number 
ePlanReview 
Description
Electrical Permit - New: New single family dwelling.
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/10/200712/10/200712/10/2007PPASS
DetailsWilliam E Thomas
Phone #: ###-#### Internet Inspection Request from: Justin Yount
. 1. final ok. .
Final12/6/200712/6/200712/6/2007PFAIL
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: Justin Yount met contractor, left correction notice, nec 210.52(C)(1) countertop receptacles shall be installed such that 24" spacing is maintained,210.8(A)(3) outdoor receptacles shall be gfci protected, BCC shall install switches for upstairs bath light and fan
Electrical Rough-In6/1/20076/1/20076/1/2007PPASS
DetailsBob Reichert
for garage and trench cover. Phone #: ###-#### Internet Inspection Request from: Justin Yount corrections made, u/g house to garage ok to cover, garage ric ok
Rough-In Permanent Service5/17/20075/18/20075/18/2007APASS
DetailsMike Kinnear
Phone #: ###-#### Internet Inspection Request from: Justin Yount ok cover ri house only. garage corrections not made 1 1/4 stapling also sub panel needs to have insolated neutral & gronding fixed p/s u/g n ok note no under ground between house & garage has been done.
Final5/15/20075/16/20075/16/2007ACANC
DetailsBob Reichert
Between Raymond and Liberty on Poplar. Phone #: ###-#### Internet Inspection Request from: Justin Yount called contr, wrong type inspection told to check when scheduling
Rough-In Permanent Service5/16/20075/16/20075/16/2007AFAIL
DetailsBob Reichert
Between Raymond and Liberty on Poplar. Phone #: ###-#### Internet Inspection Request from: Justin Yount called contr, left corr notice, 314.16 boxes shall have free space for conductors, 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 230.2 only 1 service to building shall be installed, BCC all boxes and make-up shall be done, u/g shall be inspected before cover, service to be done at ri, gec connected in crawl space