Final | 12/4/2007 | 12/5/2007 | 12/5/2007 | P | PASS |
Bob Reichert
|
|
|
Carl Phone #: ###-#### corrections made, ok to final
|
Final | 11/28/2007 | 11/29/2007 | 11/29/2007 | P | FAIL |
Bob Reichert
|
|
|
CARL Phone #: ###-#### met owner, left correction notice, nec 408.4 circuit directory shall be complete, clear and concise for each circuit, 312.5 abrasion protection shall be provided for all conductors entering enclosure ( gec), 110.12(A) all unused openings shall be closed, in panel ( breaker blanks), 210.70(A)(2)(c) shall provide lighting switch at top of stairs and at bottom
|
Final | 7/26/2007 | 7/27/2007 | 7/27/2007 | A | NR |
William E Thomas
|
|
|
carl - please call 1/2 hr prior to inspection Phone #: ###-#### 1. still has a little work left to be done.
|
Electrical Rough-In | 5/15/2007 | 5/16/2007 | 5/16/2007 | P | CANC |
Bob Reichert
|
|
|
carl ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith wrong type request
|
Rough-In Permanent Service | 5/16/2007 | 5/16/2007 | 5/16/2007 | P | PASS |
Bob Reichert
|
|
|
carl ; Phone #: ###-#### Internet Inspection Request from: Patricia Smith ric ok, p/s o/h n ok
|
Conference | 4/19/2007 | 4/20/2007 | 4/20/2007 | P | DONE |
Bob Reichert
|
|
|
carl; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles talked about wiring new shop, new shop service
|