Final | 8/29/2007 | 8/30/2007 | 8/30/2007 | A | PASS |
Jack Frank
|
|
|
PLEASE CLOSE THIS OUT; ANOTHER CONTRACTOR WIRED THE POOL EQUIPMENT Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack
|
Electrical Rough-In | 6/26/2007 | 6/27/2007 | 6/27/2007 | P | PART |
Jack Frank
|
|
|
EQUIPOTENTIAL GRID Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack e grid ok corrections made
|
Electrical Rough-In | 6/26/2007 | 6/26/2007 | 6/26/2007 | P | FAIL |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 6/26/2007 at 8:52:26 AM. Contact: ###-####. called rebar not install per NEC 680.26 (C) and electical newws brief do not cover posted, 12" squares and shall start from edgwe of pool 3 ft out no gaps allowed
|
Electrical Rough-In | 5/8/2007 | 5/9/2007 | 5/9/2007 | A | PART |
Jack Frank
|
|
|
UG CONDUIT FOR SWIMMING POOL Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack ok
|
Electrical Rough-In | 4/23/2007 | 4/24/2007 | 4/24/2007 | A | PASS |
Bob Reichert
|
|
|
POOL BONDING Phone #: ###-#### Internet Inspection Request from: Lee VanSchoiack pool bonding ok
|