Permit Information
Permit NumberELE07-02081
StatusFinaled
Name PRO-TEC SYSTEMS
Site Address 2013 S DENELL WAY
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final9/4/20079/4/20079/4/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 9/4/2007 at 11:17:33 AM. Contact: ###-####. corrections made, ok to final
Final8/31/20078/31/20078/31/2007PFAIL
DetailsJack Frank
wayne; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
corr called 250.148 grd all metal boxes , 314.16 box fill handy box furnace, 408.4 panel schedule be specific purpose and use
Permanent Service6/13/20076/13/20076/13/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/13/2007 at 10:36:47 AM. Contact: ###-####. ok to backfill gec, p/s u/g n ok
Rough-In Permanent Service6/11/20076/11/20076/11/2007PCANC
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/11/2007 at 11:09:26 AM. Contact: ###-####. wrong type request, see ri
Electrical Rough-In6/11/20076/11/20076/11/2007PPASS
DetailsBob Reichert
Scheduled by a contractor via Hello! on 6/11/2007 at 11:09:26 AM. Contact: ###-####. ok to pour gec, ric ok
Rough-In Permanent Service6/8/20076/8/20076/8/2007PFAIL
DetailsWilliam E Thomas
Scheduled by a contractor via Hello! on 6/8/2007 at 8:45:59 AM. Contact: ###-####.
1. 1 1/4" nail plating everywhere
2. 1 1/4" conductors parallel to framing members--garage
3. 2' walls kitchen, diningroom, and by the mudroom.
4. 6'-12' spacing in the master bdrm