Final | 9/4/2007 | 9/4/2007 | 9/4/2007 | P | PASS |
Jack Frank
|
|
|
Judy; Phone #: ###-#### Internet Inspection Request from: Hattie James ok needs to correct reversed polarity one bedrm recept
|
Electrical Rough-In | 6/14/2007 | 6/15/2007 | 6/15/2007 | A | PASS |
Bob Reichert
|
|
|
judith; Phone #: ###-#### corrections made, ric ok
|
Final | 6/14/2007 | 6/15/2007 | 6/15/2007 | A | CANC |
Jack Frank
|
|
|
judith; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles should be r/i
|
Electrical Rough-In | 6/13/2007 | 6/14/2007 | 6/14/2007 | A | FAIL |
Jack Frank
|
|
|
judith; Phone #: ###-#### Internet Inspection Request from: Cathy Chiles corr. met with owner210.52(A) outlet spacing also 2ft wall,300.4(A)(1)&(D) nail plates and 11/4", note #12 and #14 mixed at smokes, complete all makeup, needs listed fan box, afci, 6" free length
|