ELE-Aging Inspection | 12/16/2009 | 12/16/2009 | 12/18/2009 | | CANC |
Jack Frank
|
|
|
|
DOC - Permit Expired | 12/18/2009 | 12/18/2009 | 12/18/2009 | A | PASS |
Jack Frank
|
|
|
no action for almost 2 years
|
Electrical Rough-In | 2/27/2008 | 2/27/2008 | 2/27/2008 | P | PASS |
Bob Reichert
|
|
|
nathan Phone #: ###-#### corrections made, called,, ric ok
|
Electrical Rough-In | 2/25/2008 | 2/25/2008 | 2/25/2008 | P | FAIL |
Bob Reichert
|
|
|
nathan-please call at least 30 mins prior to inspection Phone #: ###-#### met owner, left correction notice NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 300.14 shall provide 6" free conductor length in box for splice connection point, 110.12(C) there shall be no broken parts (box knockouts), 110.3(B) listed equipment shall be instslled per manufacturer's instructions- no loose crimps, 334.30 nm cable shall be stapled or secured within 8" of box, 210.52(A)(2) shall provide receptacle in 2" wall space, BCC no violations shall be retained
|
Conference | 1/24/2008 | 1/25/2008 | 1/25/2008 | A | DONE |
Bob Reichert
|
|
|
heidi Phone #: ###-#### met owner talked about receptacle spacing, make-up, 6" free conductor length, ground metal boxes, told owner that we can only come out 2 times or he will have to get licensed contractor to do the work, talked about afci breakers, clean up panel, nm cable in connectors, stapling, nail plates, 1 1/4" for holes and nm cable, told to have all job ready for ri inspection
|
Electrical Rough-In | 1/16/2008 | 1/22/2008 | 1/22/2008 | A | NR |
Mike Kinnear
|
|
|
heidi - partial insp. only Phone #: ###-#### job not ready & home owner who did the wiring not at job site. missing wall spacing, devises all ready installed,& stapling not correct. told wife to recall & call bob for appointment.
|
Conference | 6/21/2007 | 6/22/2007 | 6/22/2007 | A | DONE |
Bob Reichert
|
|
|
nathan Note: reminder made appt with insp 8:30 Phone #: ###-#### looked at plans, reviewed bring up new to code and owner to do all work
|