Permit Information
Permit NumberELE07-02192
StatusFinaled
Name TRI-STATE ELECTRIC
Site Address 3101 W CASSIA ST
Project NameSOUTH JUNIOR HIGH SCHOOL
Customer Number 
ePlanReview 
Description
Temporary Power Pole: Temp Power = South Jr. High School
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
ELE-Aging Inspection10/20/200810/20/200810/27/2008 DONE
DetailsBob Reichert
ok to final, no esc this project
Final10/27/200810/27/200810/27/2008APASS
DetailsBob Reichert
ok to final temp power
Final8/14/20088/14/20088/14/2008PPART
DetailsWilliam E Thomas
. .1. T/O is approved. . .
. .2. This does not include Area *A*, which is still under cunstruction. . .
. .3. They must still observe all requirements and conditions as required by Life Safety and the Building Department. . .
Electrical Rough-In7/5/20077/5/20077/5/2007PPART
DetailsBob Reichert
ok to cover part of u/g from center area disc to about 20' and from north disc back about 30' with direct burial cable. Will see conduits later
Electrical Rough-In6/26/20076/27/20076/27/2007ACANC
DetailsBob Reichert
CONTACT: STEVE HESS - UNDERGROUND INSPECTION PLEASE Phone #: ###-#### Internet Inspection Request from: Deb Gooden wrong type request, see t/s
Temporary Service6/27/20076/27/20076/27/2007ACANC
DetailsBob Reichert
CONTACT: STEVE HESS - UNDERGROUND INSPECTION PLEASE Phone #: ###-#### Internet Inspection Request from: Deb Gooden corrections made, t/s u/g n ok
Temporary Service6/25/20076/26/20076/26/2007ANR
DetailsMike Kinnear
Steve; Phone #: ###-#### Internet Inspection Request from: Darla Downs conf regarding over current protection on disconnects & neut. required at first disconnect
Temporary Service6/20/20076/20/20076/20/2007PFAIL
DetailsBob Reichert
steve; Phone #: ###-#### Internet Inspection Request from: Victoria Apatang called, added to corr notice, corrections not made, created more, 250.46(C) gec shall be continuous, 250.55 gec per table #2, on 200a disc, 250.92(B) bonding shall be provided for service, 110.14 connection such as scraping paint for lugs, fee due
Temporary Service6/18/20076/19/20076/19/2007AFAIL
DetailsBob Reichert
CONTACT: STEVE HESS Phone #: ###-#### Internet Inspection Request from: Deb Gooden called, left corr notice, nec 312.5 abrasion protection shall be provided for all conductors entering enclosures, 250.53 (G) rod shall not be over 45 degree, 250.24(A) gec shall tie to each service to the grounded srevice conductor, 314.28(A)(2) pull box shall be sized per number of raceways entering and leaving for angle pulls(22" min?), 110.14(A) connections shall be tight