Final | 10/23/2007 | 10/24/2007 | 10/24/2007 | A | PASS |
Jack Frank
|
|
|
steve Phone #: ###-#### ok
|
Electrical Rough-In | 9/10/2007 | 9/10/2007 | 9/10/2007 | P | PASS |
Jack Frank
|
|
|
larry Phone #: ###-#### ok
|
Electrical Rough-In | 8/15/2007 | 8/15/2007 | 8/15/2007 | P | FAIL |
Jack Frank
|
|
|
steve Phone #: ###-#### Note: after 2:00 pm please corr. do not cover posted called, 300.4 nail plates and 11/4" for cables parallel, note inside and outside edges for holes and cables parallel, 314.20 outside boxes shall be flush with finish siding, 300.14 free length grd wires cut short, if inside not finished protect cables run horizontally 334.15, told owner requirements at time of conference, and do not give me neighbor's phone number to discuss code questions I only deal with homeowner
|
Conference | 7/30/2007 | 7/30/2007 | 7/30/2007 | P | DONE |
Jack Frank
|
|
|
Steve- ###-#### conf. ok needs 11/4" holes and parallel, replace 2gang boxes broken clamps, single gang broken out KO, protect cables run horizontally no wall covering, provide switch point of acces to attic, complete all makeup, move 2 gang jbox for outside light
|