ELE-Aging Inspection | 1/14/2013 | 1/14/2013 | 1/14/2013 | | DONE |
Bob Reichert
|
|
|
see doc expire
|
DOC - Permit Expired | 1/14/2013 | 1/14/2013 | 1/14/2013 | P | PASS |
Bob Reichert
|
|
|
no activity, ok doc expire per other disciplines
|
ELE-Aging Inspection | 10/15/2012 | 10/15/2012 | 10/15/2012 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 7/16/2012 | 7/16/2012 | 7/16/2012 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 4/16/2012 | 4/16/2012 | 4/16/2012 | | DONE |
Bob Reichert
|
|
|
called, still under construction
|
ELE-Aging Inspection | 1/16/2012 | 1/16/2012 | 1/17/2012 | | DONE |
Bob Reichert
|
|
|
still under construction
|
ELE-Aging Inspection | 10/17/2011 | 10/17/2011 | 10/17/2011 | | DONE |
Bob Reichert
|
|
|
still under construcrion
|
ELE-Aging Inspection | 7/18/2011 | 7/18/2011 | 7/18/2011 | | DONE |
Bob Reichert
|
|
|
no activity, still under construction
|
ELE-Aging Inspection | 4/18/2011 | 4/18/2011 | 4/21/2011 | | DONE |
Bob Reichert
|
|
|
still under consruction
|
ELE-Aging Inspection | 2/15/2011 | 2/15/2011 | 2/15/2011 | | DONE |
Bob Reichert
|
|
|
still under construction
|
Electrical Rough-In | 12/16/2010 | 12/16/2010 | 12/16/2010 | P | PASS |
Bob Reichert
|
|
|
Still need R/I on bath only--Phil Phone #: ###-#### up bath ok cover
|
ELE-Aging Inspection | 1/29/2010 | 1/29/2010 | 1/29/2010 | | DONE |
Bob Reichert
|
|
|
no activity, see doc expire
|
DOC - Permit Expired | 1/29/2010 | 1/29/2010 | 1/29/2010 | A | PASS |
Bob Reichert
|
|
|
no activity, ok to doc expire
|
ELE-Aging Inspection | 11/27/2009 | 11/27/2009 | 12/4/2009 | | DONE |
Bob Reichert
|
|
|
no activity
|
ELE-Request for Extension | 8/28/2008 | 8/28/2008 | 8/28/2008 | P | PASS |
Jim Schmer
|
|
|
Phill Duman ###-####//doing the project himself so taking a little longer than expected this time only jms
|
Electrical Rough-In | 2/6/2008 | 2/6/2008 | 2/6/2008 | P | PASS |
Bob Reichert
|
|
|
phil Phone #: ###-#### ric ok upper level
|
Electrical Rough-In | 2/1/2008 | 2/4/2008 | 2/4/2008 | P | CANC |
Bob Reichert
|
|
|
phil- Phone #: ###-#### see conference
|
Conference | 2/4/2008 | 2/4/2008 | 2/4/2008 | P | DONE |
Bob Reichert
|
|
|
phil- Phone #: ###-#### met owner, talked about receptacle spacing, make-up, 1 1/4" holes and protect nm cable
|
Electrical Rough-In | 11/9/2007 | 11/9/2007 | 11/9/2007 | P | PASS |
Bob Reichert
|
|
|
ri ok lower part only, done 11-8-07
|
Electrical Rough-In | 11/8/2007 | 11/9/2007 | 11/9/2007 | P | CANC |
Bob Reichert
|
|
|
Phil; Phone #: ###-#### Internet Inspection Request from: Barbara Stitt
|
Electrical Rough-In | 11/7/2007 | 11/7/2007 | 11/7/2007 | P | NR |
Bob Reichert
|
|
|
phil-- ###-#### -call 1st before insp reviewed make-up wire stapling, will call when done. Note: will have to raise mast. Trusses are too high, not enough clearance to roof.
|
Permanent Service | 8/21/2007 | 8/21/2007 | 8/21/2007 | P | PASS |
Bob Reichert
|
|
|
phil Phone #: ###-#### corrections made, p/s o/h rec ok
|
Permanent Service | 8/20/2007 | 8/20/2007 | 8/20/2007 | P | FAIL |
Bob Reichert
|
|
|
Phil; Phone #: ###-#### Internet Inspection Request from: Hattie James called left corr notice, nec 250.52(A) metal water pipe entering building within 5' shall be used a part of grounding electrode system, 250.53(B) electrodes shall be minimum 6' apart, 250.53(G) electrodes shall be 8' long and flush with or below ground level, 110.3(A) shall not use metal romex connector for abrasion protection (plastic ok), Note: ground clamps shall br installed correctly 110.12(A) all unused openings shall be closed to afford protection equivalent to enclosure
|
Conference | 8/17/2007 | 8/17/2007 | 8/17/2007 | P | DONE |
Bob Reichert
|
|
|
Phill Duman ###-#### talked about service, no overcurrent devices in closet, maybe make old panel j-box, mast height, 4-wire to range and dryer
|