Permanent Service | 4/18/2008 | 4/18/2008 | 4/18/2008 | P | PASS |
Bob Reichert
|
|
|
Please call Project Manager, Todd Hall (###-####) prior to inspection. Phone #: ###-#### Internet Inspection Request from: Tracy Robertson corrections made, convert temporary service to regular service- p/s o/h rec ok
|
Final | 4/18/2008 | 4/18/2008 | 4/18/2008 | P | PASS |
Bob Reichert
|
|
|
Please call Project Manager, Todd Hall (###-####) prior to inspection. Phone #: ###-#### Internet ok to final
|
Electrical Rough-In | 9/25/2007 | 9/25/2007 | 9/25/2007 | P | FAIL |
Bob Reichert
|
|
|
SERVICE - Water Bonding Inspection. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson called contr, told nec 250.24 shall have grounding electrode conductor connected to grounded conductor at service, i.e. move water pipe ground from left service to meter enclosure, told contr did not leave corr notice, since he will call back and we need to see other items
|
Conference | 9/21/2007 | 9/21/2007 | 9/21/2007 | P | CANC |
Jack Frank
|
|
|
Requested conference with Bob R. for 12-noon as per Bob''s request with Todd Hall (###-####) Phone #: ###-#### Internet Inspection Request from: Tracy Robertson 315 talked with contr about making corrections as on correction notice, contractor called, said would cancel conference until contractor talked with 324
|
Permanent Service | 9/20/2007 | 9/20/2007 | 9/20/2007 | P | PART |
Jack Frank
|
|
|
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see added t/s, corr. posted on what is required for p/s Bob R has copy of corr.
|
Temporary Service | 9/20/2007 | 9/20/2007 | 9/20/2007 | P | PART |
Jack Frank
|
|
|
Please inspect main service outside and sub-panel inside. Water pipe is bonded to at the sub-panel (could not locate water main within 5'' of entrance). Todd Hall spoke with Jim Schmear on 9-19 regarding approval to bond to water pipe inside of residence. Customer is building a soffit for protection of SER and NMBs ran along ceiling in bedroom where sub-panel is located. 3-wire range and dryer are extended to main panel outside. Home owner moved cable TV aside on soffit above main service. Home owner needs IDPCO reconnection in afternoon. Call Todd Hall if any questions. ###-#### Phone #: ###-#### Internet Inspection Request from: Tracy Robertson p/s is on a temp basis for now t/s o/h rec ok
|
Rough-In Permanent Service | 9/7/2007 | 9/7/2007 | 9/7/2007 | P | CANC |
Bob Reichert
|
|
|
Please call Todd (###-####) PRIOR to inspection to meet at site. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson see conf
|
Conference | 9/7/2007 | 9/7/2007 | 9/7/2007 | P | DONE |
Bob Reichert
|
|
|
Please call Todd (###-####) PRIOR to inspection to meet at site. Thank you!! Phone #: ###-#### Internet Inspection Request from: Tracy Robertson met contr, talked about grounding bushings at service, no ser in raceway, metal water pipe, 4-wire for range and dryer, clean area over top of panels, move or cap water pipe below panel
|
Permanent Service | 9/4/2007 | 9/5/2007 | 9/5/2007 | P | CANC |
Bob Reichert
|
|
|
As late in the afternoon as possible please, this is a service change. Phone #: ###-#### Internet Inspection Request from: Tracy Robertson Inspection cancelled from web by: Tracy Robertson
|