Final | 10/29/2007 | 10/30/2007 | 10/30/2007 | A | PASS |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 10/29/2007 at 3:47:14 PM. Contact: ###-####. ok final
|
Permanent Service | 10/4/2007 | 10/4/2007 | 10/4/2007 | P | CANC |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:57 AM. Contact: ###-####. see added r/i
|
Electrical Rough-In | 10/4/2007 | 10/4/2007 | 10/4/2007 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 10/4/2007 at 10:19:57 AM. Contact: ###-####. u/g house to garage ok
|
Electrical Rough-In | 9/7/2007 | 9/7/2007 | 9/7/2007 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 9/7/2007 at 8:45:33 AM. Contact: ###-####. corrections made, ric ok, Note: no inspection made from house to garage u/g
|
Electrical Rough-In | 9/6/2007 | 9/6/2007 | 9/6/2007 | P | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 9/6/2007 at 10:35:17 AM. Contact: ###-####. called contr, corrections not all made, fee due, crossed off what fixed on corr notice
|
Rough-In Permanent Service | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | CANC |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James see r/i and p/s
|
Electrical Rough-In | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | FAIL |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James called, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.53(A) recpt shall be at rear of dwelling, 210.52(A)(2) 2' walls shall have recpts installed, 312.5 shall provide abrasion protection for all conductors entering enclosures, BCC all u/g shall be inspected before cover, address shall be posted
|
Permanent Service | 9/5/2007 | 9/5/2007 | 9/5/2007 | P | PASS |
Bob Reichert
|
|
|
Tom; Phone #: ###-#### Internet Inspection Request from: Hattie James p/s u/g n ok
|