Final | 2/4/2008 | 2/5/2008 | 2/5/2008 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called, left survey, nec 330.30(B) mc cable shall be secured within 12" of box, 358.30(A) emt shall be secured within 3' of box, no structural card to sign, see ri for wall cover only
|
Electrical Rough-In | 2/5/2008 | 2/5/2008 | 2/5/2008 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot see final for survey, ric ok, walls only
|
Permanent Service | 1/4/2008 | 1/7/2008 | 1/7/2008 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot p/s u/g n ok-1 meter only
|
Electrical Rough-In | 11/26/2007 | 11/27/2007 | 11/27/2007 | A | PART |
Bob Reichert
|
|
|
Inspect trench Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot u/g going north from building under drive fails depth- CAN NOT USE, conduit going northwest from building under drive is ok to use
|
Conference | 11/20/2007 | 11/26/2007 | 11/26/2007 | A | DONE |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot met builder and contractor, this one time we look at outside ends of raceway under driveway only, they wll call for ri later
|
Electrical Rough-In | 11/19/2007 | 11/19/2007 | 11/19/2007 | P | PASS |
Bob Reichert
|
|
|
Inspect west exterior wall (menu board area) Phone #: ###-#### Internet Inspection Request from: Barbara Szurgot called contr, told to change address on permit to 6573, also told to sawcut u/g for inspection or can't use. ok to cover outside west board only for drive in area
|