Final | 12/27/2007 | 12/27/2007 | 12/27/2007 | P | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok
|
Final | 12/26/2007 | 12/26/2007 | 12/26/2007 | P | NR |
Jack Frank
|
|
|
Internet Inspection Request from: Dan Rohl conference ok only needs manufactures instructions for J tub access size, shall add outlet in backsplash for spacing island counter 2ft 4ft rule when not flat across entire surface
|
Conference | 10/30/2007 | 10/31/2007 | 10/31/2007 | A | CANC |
Jack Frank
|
|
|
Tile floor heat inspection Phone #: ###-#### Internet Inspection Request from: Dan Rohl see added r/i
|
Electrical Rough-In | 10/31/2007 | 10/31/2007 | 10/31/2007 | A | PASS |
Jack Frank
|
|
|
Tile floor heat inspection Phone #: ###-#### Internet Inspection Request from: Dan Rohl ok master bath and mud rm
|
Permanent Service | 10/9/2007 | 10/9/2007 | 10/9/2007 | P | PASS |
Jack Frank
|
|
|
p/s u/g new ok
|
Electrical Rough-In | 9/27/2007 | 9/27/2007 | 9/27/2007 | P | PASS |
Jack Frank
|
|
|
steve - re-inspection Phone #: ###-####
|
Rough-In Permanent Service | 9/24/2007 | 9/26/2007 | 9/26/2007 | A | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl corr. called 210.52(C)(1) needs recept left of kit sink, 314.16 box fill, 110.3(A&B) replace broken box pantry, manufactures instructions for mico wave circuit, both high and low voltage wiring nail plates and 11/4" parallel, low voltage 362.30, 362.6 secure ent 3ft of box, use listed fittings,conn at cabinet, do not cover posted
|
Permanent Service | 9/26/2007 | 9/26/2007 | 9/26/2007 | A | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Dan Rohl p/s u/g new ok
|