Final | 2/26/2009 | 2/27/2009 | 2/27/2009 | A | PASS |
Bob Reichert
|
|
|
dale - please call 1/2 hr prior so he can meet you there Phone #: ###-#### met owner, ok to final, no esc this project
|
Final | 2/23/2009 | 2/24/2009 | 2/24/2009 | A | CANC |
Bob Reichert
|
|
|
Dale please call 1/2 hr brfore going out Phone #: ###-####
|
Final | 12/14/2007 | 12/14/2007 | 12/14/2007 | P | CANC |
Bob Reichert
|
|
|
Dale; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt wrong type request, see ri
|
Electrical Rough-In | 12/14/2007 | 12/14/2007 | 12/14/2007 | P | PASS |
Bob Reichert
|
|
|
Dale; Phone #: ###-#### Internet Inspection Request from: Cathy Weisshaupt corrections made, called owner, ric ok garage, kitchen, family room
|
Final | 12/11/2007 | 12/11/2007 | 12/12/2007 | P | CANC |
Bob Reichert
|
|
|
dale Phone #: ###-#### wrong type request, see ri dated 12/12/07
|
Electrical Rough-In | 12/12/2007 | 12/12/2007 | 12/12/2007 | P | PASS |
Bob Reichert
|
|
|
corrections made garage only, ric ok- house needs 6" free conductor 2 places in kitchen, nail plate, strap nm cable over panel, code references in garage on correction notice that 370 left
|
Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 | P | FAIL |
Jack Frank
|
|
|
dale Note: please call 1/2 hr prior to inpsection so he show where to see Phone #: ###-#### corr called 300.4 nail plates, 300.14 needs 6" free length, 110.14(B) needs splicing devices wires just twisted together, 210.70 lights for outside exits, and accessible attic, 110.3(B) needs main breaker and backfed clip shop p/s needs 2 grd rods, 250.32, 250.119(A) shall not ID #6 or smaller equip grd
|
Electrical Rough-In | 12/3/2007 | 12/3/2007 | 12/3/2007 | P | PART |
Jack Frank
|
|
|
dale Note: please call 1/2 hr prior to inpsection so he show where to see Phone #: ###-#### u/g ok only
|
Rough-In Permanent Service | 11/30/2007 | 11/30/2007 | 11/30/2007 | P | CANC |
Bob Reichert
|
|
|
Dale Phone #: ###-####--Customer called and canceled-11-30-07 @ 12:22 BAS
|
Permanent Service | 11/20/2007 | 11/20/2007 | 11/20/2007 | P | PASS |
Bob Reichert
|
|
|
Dale Phone #: ###-#### p/s u/g rec ok
|
Conference | 11/13/2007 | 11/13/2007 | 11/13/2007 | P | DONE |
Bob Reichert
|
|
|
dale lloyd - ###-#### cell - call 1st for access talked about service and panel locations- not in closet, and clearances
|