Permit Information
Permit NumberELE07-03963
StatusFinaled
Name ENTERPRISE ELECTRIC
Site Address 9764 W KLONDIKE CT
Project Name 
Customer Number344-0441
ePlanReview 
Description
Electrical Permit - Repair: HOUSE ADDITION
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final3/26/20083/27/20083/27/2008APASS
DetailsBob Reichert
Reinspection. Phone #: ###-#### Internet Inspection Request from: BRENDA HURST corrections made, ok to final
Final3/19/20083/20/20083/20/2008AFAIL
DetailsBob Reichert
Phone #: ###-#### Internet Inspection Request from: BRENDA HURST called, left correction notice, NEC 408.4 circuit directory shall be clear, concise and explanatory for each circuit, 314.25 in completed installations, each box shall have a cover installed, 410.8 closet light shall be 12" from edge of fixture to edge of shelf
Electrical Rough-In12/3/200712/3/200712/3/2007PPASS
DetailsBob Reichert
Corrections have been made and job is ready for re-insp. Randi''s # ###-####. Thanks Phone #: ###-#### Internet Inspection Request from: BRENDA HURST called contractor, corrections made, ric ok
Electrical Rough-In11/29/200711/30/200711/30/2007AFAIL
DetailsBob Reichert
RUFF IN PLEASE, CAN CALL RANDI AT ###-#### Phone #: ###-#### Internet Inspection Request from: BRENDA HURST electricians did not appear to do work, gen contractor met on job, called contrator, left correction notice, nec 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing member, 334.30 nm cable shall not be stapled on edge, 300.14 at least 6" free conductor shall be left at each box, then made-up, 110.14(A) connection of conductors to terminal parts shall ensure a thoroughly good connection, possible further items will be found at re-inspection, told to provide approved access to upper part