Final | 1/10/2008 | 1/10/2008 | 1/10/2008 | P | PASS |
Pat Lass
|
|
|
Scheduled by a contractor via Hello! on 1/10/2008 at 9:44:44 AM. Contact: ###-####.
|
Final | 1/9/2008 | 1/10/2008 | 1/10/2008 | A | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 1/9/2008 at 12:03:54 PM. Contact: ###-####. called electrician, left correction notice, nec 406.4 receptacles in kitchen and dining area shall be securely mounted, 410.4 fixture in downstairs shower shall be listed for wet location, 410.8(B) closet fixture shall be completely enclosed
|
Electrical Rough-In | 12/11/2007 | 12/12/2007 | 12/12/2007 | A | PASS |
Mike Kinnear
|
|
|
rick Phone #: ###-#### ok cover ri note what was exposed
|
Electrical Rough-In | 12/10/2007 | 12/11/2007 | 12/11/2007 | A | PART |
Pat Lass
|
|
|
Rough-in 5 smoke detectors in home Phone #: ###-#### Internet Inspection Request from: Rick Beckman other work has been done without a permit. homeowner is going to have rick take over this work and add it to this permit. I posted a stop work.
|