Final | 2/7/2008 | 2/8/2008 | 2/8/2008 | A | PASS |
Jack Frank
|
|
|
jake - please call for access Phone #: ###-#### ok
|
Permanent Service | 1/9/2008 | 1/10/2008 | 1/10/2008 | A | PASS |
Bob Reichert
|
|
|
jake Phone #: ###-#### p/s, exst meter pak, rec, ok
|
Electrical Rough-In | 1/8/2008 | 1/9/2008 | 1/9/2008 | A | PASS |
Bob Reichert
|
|
|
jake - please call for access Phone #: ###-#### corrections made, ric ok
|
Electrical Rough-In | 1/4/2008 | 1/4/2008 | 1/4/2008 | P | FAIL |
Bob Reichert
|
|
|
jake - please call for access Phone #: ###-#### called contractor, left correction notice, nec 300.14 at least 6" free conductor shall be in boxes from where sheath enters box, 210.11(C) (3) bathrooms shall be supplied from 20a circuit with no other outlets, 210.12(B) bedrooms shall be protected by arc-fault circuit interrupters, 250.140 shall provide for range and dryer frame grounding per 250.134 and or 1138
|