Final | 4/16/2008 | 4/16/2008 | 4/16/2008 | P | PASS |
Pat Lass
|
|
|
Final on new shed in backyard, door is open okay to enter as per homeowner. Any questions call Jimmy @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose
|
Rough-In Permanent Service | 3/26/2008 | 3/27/2008 | 3/27/2008 | A | PASS |
Pat Lass
|
|
|
re inspection on wiring in new shed Phone #: ###-#### Internet Inspection Request from: Andy Rose
|
Rough-In Permanent Service | 3/25/2008 | 3/26/2008 | 3/26/2008 | A | CANC |
Bob Reichert
|
|
|
inspection on 100amp service and wiring for outlets, this is located in new shed in backyard, door is open okay by owner to go in backyard. Any questions call Jim @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose see ri and p/s
|
Permanent Service | 3/26/2008 | 3/26/2008 | 3/26/2008 | A | PASS |
Bob Reichert
|
|
|
inspection on 100amp service and wiring for outlets, this is located in new shed in backyard, door is open okay by owner to go in backyard. Any questions call Jim @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose p/s o/h n ok
|
Electrical Rough-In | 3/26/2008 | 3/26/2008 | 3/26/2008 | A | FAIL |
Bob Reichert
|
|
|
inspection on 100amp service and wiring for outlets, this is located in new shed in backyard, door is open okay by owner to go in backyard. Any questions call Jim @ ###-#### Phone #: ###-#### Internet Inspection Request from: Andy Rose called left message, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members,314.20 in walls of combustible material, boxes shall be flush with or project from finished surface
|