Final | 8/27/2008 | 8/27/2008 | 8/27/2008 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 8/27/2008 at 5:53:46 AM. Contact: ###-####. corrections made, ok to final, signed occupancy card, no esc this project
|
Final | 8/26/2008 | 8/26/2008 | 8/26/2008 | P | DEFR |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 8/26/2008 at 10:45:49 AM. Contact: ###-####. called contractor, panel schedules, low voltage on grid strappring, showed electrician on job, correction notice been posted, no esc this project
|
Electrical Rough-In | 8/8/2008 | 8/8/2008 | 8/8/2008 | A | PASS |
Bob Reichert
|
|
|
Ceiling inspection request. PLEASE call John at ###-#### so he can meet you there. The earlier the better for John. Thanks! Phone #: ###-#### Internet Inspection Request from: John Campbell ok to cover ceiling, will open tiles for final, no esc this project
|
Permanent Service | 8/7/2008 | 8/8/2008 | 8/8/2008 | A | CANC |
Bob Reichert
|
|
|
Ceiling inspection request. PLEASE call John at ###-#### so he can meet you there. The earlier the better for John. Thanks! Phone #: ###-#### Internet Inspection Request from: John Campbell wrong type request, see ri
|
Conference | 7/30/2008 | 7/30/2008 | 7/30/2008 | P | DONE |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/30/2008 at 8:55:52 AM. Contact: ###-####. talked about abandoned fixtures ok to leave on original ceiling, said to remove tubes, no esc this project
|
Electrical Rough-In | 7/30/2008 | 7/30/2008 | 7/30/2008 | P | PART |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/30/2008 at 8:55:52 AM. Contact: ###-####. ok to cover ceilings anop, no esc this project
|
Electrical Rough-In | 7/22/2008 | 7/22/2008 | 7/22/2008 | A | FAIL |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/22/2008 at 6:29:02 AM. Contact: ###-####. met contractor, left correction notice, BCC all work shall be completed, boxes closed, no raceways or cables on grid or tiles, NEC 110.12(A) ko shall be closed in boxes, 300.11(A) conductors shall be rigidly supported, no esc this project
|
Electrical Rough-In | 7/8/2008 | 7/8/2008 | 7/8/2008 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 7/8/2008 at 6:28:46 AM. Contact: ###-####. ric walls only anop, no esc this project
|
Electrical Rough-In | 6/25/2008 | 6/26/2008 | 6/26/2008 | A | PART |
Mike Kinnear
|
|
|
Scheduled by a contractor via Hello! on 6/25/2008 at 2:40:54 PM. Contact: ###-####. ok cover ceiling note they are fixing low voltage wires later & they needed to correct whips in front of counter no esc permit in project
|
Electrical Rough-In | 6/10/2008 | 6/10/2008 | 6/10/2008 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 6/10/2008 at 9:25:17 AM. Contact: ###-####. walls ok to cover anop
|
Permanent Service | 6/10/2008 | 6/10/2008 | 6/10/2008 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 6/10/2008 at 9:26:16 AM. Contact: ###-####. p/s o/h rec ok, corrections made
|
Conference | 5/29/2008 | 5/29/2008 | 5/29/2008 | P | DONE |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 5/29/2008 at 7:22:56 AM. Contact: ###-####. talked with contractor, gave correction notice for him to work with general on service changes- NEC 230.2 a building shall be supplied by only one service, 230.72(A) disconnects shall be grouped and marked to indicate the load served, no esc
|
Electrical Rough-In | 5/20/2008 | 5/20/2008 | 5/20/2008 | A | PART |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 5/20/2008 at 6:07:24 AM. Contact: ###-####. ok to cover ceilings anop
|
Electrical Rough-In | 4/25/2008 | 4/25/2008 | 4/25/2008 | P | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 4/25/2008 at 9:22:12 AM. Contact: ###-####. hard lids only ok to cover
|
Electrical Rough-In | 4/23/2008 | 4/23/2008 | 4/23/2008 | A | PASS |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 4/23/2008 at 7:27:37 AM. Contact: ###-####. walls only ric ok, hard lids not ready, will have dropped ceiling
|
Electrical Rough-In | 4/18/2008 | 4/21/2008 | 4/21/2008 | A | CANC |
Bob Reichert
|
|
|
Scheduled by a contractor via Hello! on 4/18/2008 at 2:53:20 PM. Contact: ###-####. contractor called, asked to cancel
|