Final | 9/26/2008 | 9/26/2008 | 9/26/2008 | P | PASS |
Jack Frank
|
|
|
please reinspect master bath tub thank you for your time on this. Phone #: ###-#### Internet Inspection Request from: Alan Lusk ok tub labeled
|
Final | 9/25/2008 | 9/26/2008 | 9/26/2008 | A | FAIL |
Jack Frank
|
|
|
entry code 19690 Phone #: ###-#### Internet Inspection Request from: Alan Lusk all violations corrected but still need listing and label for jtub , where is it ?
|
Final | 9/25/2008 | 9/25/2008 | 9/25/2008 | P | FAIL |
Bob Reichert
|
|
|
Bill Entry code 19690 Phone #: ###-#### Internet Inspection Request from: Alan Lusk called, left correction notice, NEC 352.30 shall strap rnc within 3' of conduit termination, 408.4 shall provide circuit directoru at outside panel, 210.52)C)(3),(4), shall provide receptacle at end of peninsula separated by cook-top, 422.31(B) shall provide dishwasher lock-out, 110.3(B) shall provide listing for jetted tub and proper access hole per manufacturers instructions
|
Rough-In Permanent Service | 5/21/2008 | 5/21/2008 | 5/21/2008 | P | PASS |
William E Thomas
|
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk . .1. ri ok. . . . .2. p/s u/g n ok. . .
|
Rough-In Permanent Service | 5/19/2008 | 5/20/2008 | 5/20/2008 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Alan Lusk called left correction notice, 210.52(A)(1)&(2) shall mount receptacles in 2' wall space and not over 6' from broken wall line such as door- see kitchen, living room, open area by hall, 314.16 box shall not be overfilled with conductors per calculations-living room, 300.4(A) edge of bored holes shall be 1 1/4" from edge of framing members, 250.10 ground clamp shall be protected, BCC approved set of plans shall be on job
|