Final | 8/28/2008 | 8/28/2008 | 8/28/2008 | P | PASS |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson ok
|
Rough-In Permanent Service | 5/27/2008 | 5/28/2008 | 5/28/2008 | A | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson corrections made, ric ok, p/s u/g n ok
|
Final | 5/23/2008 | 5/23/2008 | 5/23/2008 | P | CANC |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson see added r/i p/s
|
Rough-In Permanent Service | 5/23/2008 | 5/23/2008 | 5/23/2008 | P | FAIL |
Jack Frank
|
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson corr called 210.52(C) outlets required for countertops left and right of refer, 210.52(B) remove outlet in hallway to garage from small appliance branch circuit, 110.3(B) shall prive 30"x15" access for jtub per manufactures instructions, 110.3(A) wire all vacuum outlet note shall not be on kit or bath circuits,300.15 ent at low voltage cabinet shall terminate in connectors
|
Rough-In Permanent Service | 5/22/2008 | 5/22/2008 | 5/22/2008 | P | FAIL |
William E Thomas
|
|
|
Phone #: ###-#### Internet Inspection Request from: Therrin Robertson . .1. B.C.C. requires that there be an approved set of plans on site. . .
|