Final | 8/5/2008 | 8/5/2008 | 8/5/2008 | P | PASS |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Lynn Cable corrections made, ok to final
|
Final | 8/3/2008 | 8/4/2008 | 8/4/2008 | A | FAIL |
Bob Reichert
|
|
|
Phone #: ###-#### Internet Inspection Request from: Lynn Cable called, left correction notice, NEC 408.4 shall provide panel schedules that are clear, concise, and explanatory at pool equipment and main panel, 352.30(A) rnc shall be securely fastened within 3' of box or conduit termination, 680.22(A)(3) shall provide receptacle within 10' min or 20' maximum from inside pool wall, 110.12(C) there shall be no broken parts(top of pull box),110.14 all bonding connections shall be tight
|
Rough-In Permanent Service | 7/30/2008 | 7/31/2008 | 7/31/2008 | A | CANC |
Bob Reichert
|
|
|
Potting compound Phone #: ###-#### Internet Inspection Request from: Lynn Cable wrong type request, see ri
|
Electrical Rough-In | 7/31/2008 | 7/31/2008 | 7/31/2008 | P | PASS |
Bob Reichert
|
|
|
Potting compound Phone #: ###-#### Internet Inspection Request from: Lynn Cable potting only ok
|
Electrical Rough-In | 7/30/2008 | 7/30/2008 | 7/30/2008 | P | NR |
Bob Reichert
|
|
|
Need Inspection on Potting compound -Final? Phone #: ###-#### Internet Inspection Request from: Lynn Cable just finished pool gunnite, could not get in to see potting, told to call for am inspection
|
Electrical Rough-In | 6/19/2008 | 6/20/2008 | 6/20/2008 | A | PART |
Jack Frank
|
|
|
main underground Phone #: ###-#### Internet Inspection Request from: Lynn Cable ok j box installed
|
Electrical Rough-In | 6/18/2008 | 6/19/2008 | 6/19/2008 | A | FAIL |
Bob Reichert
|
|
|
main underground Phone #: ###-#### Internet Inspection Request from: Lynn Cable called, left correction notice, nec 352.26 there shall not be over 360 degrees total bends in rnc between pull points
|
Electrical Rough-In | 6/11/2008 | 6/11/2008 | 6/11/2008 | P | PASS |
Bob Reichert
|
|
|
pool bonding and light nitches Phone #: ###-#### Internet Inspection Request from: Lynn Cable pool bonding and light niches ok to cover, u/g pool to equipment ok to cover, no power or other u/g seen
|