Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberELE08-01580
StatusFinaled
Name ANDERSON & WOOD CONSTRUCTION
Site Address 3733 W QUAIL HOLLOW DR
Project Name 
Customer Number08-7067
ePlanReview 
Description
Electrical Permit - New: Electrical work
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final10/15/200810/16/200810/16/2008APASS
DetailsJack Frank
Final Inspection. Please call Rick Sendra @ ###-#### prior to inspection in order to gain entrance. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
ok survey posted 314.43 screws not allowed in plastic box kit. left of sink, 210.8 gfci outlets 6ft of laundry sink
Final10/8/200810/9/200810/9/2008AFAIL
DetailsJack Frank
Final Inspection. Please call Rick Sendra @ ###-#### to gain entry 30 minutes prior to inspection. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
met contr corr posted 210.52(A) outlet spacing sewing rm and living rm by pocket door downstairs 210.52(C) outlet spacing left of kit sink, 410.8 fixture clearwence downstairs bed rm closet, 210.8 gfci not working laundry rm and mech. rm
Final10/7/200810/8/200810/8/2008ACANC
DetailsBob Reichert
Final Inspection. Please call Rick Sendra @ ###-#### 30 minutes prior to inspection to gain entry. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson talked with contractor, will reschedule for am tomorrow
Electrical Rough-In7/10/20087/10/20087/10/2008PPASS
DetailsWilliam E Thomas
R.I. Reinspect. Bob J. ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
. .1. ri ok. . .
Permanent Service7/10/20087/10/20087/10/2008PPASS
DetailsWilliam E Thomas
R.I. Reinspect. Bob J. ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
. .1. p/s u/g n ok. . .
Permanent Service7/7/20087/8/20087/8/2008PFAIL
DetailsJack Frank
Permanent Service inspection. Bob J. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson see r/i request correction
Electrical Rough-In7/7/20087/8/20087/8/2008PFAIL
DetailsJack Frank
Rough In inspection. Bob J. Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr met contr. 210.52(A) needs outlets 1 in NW bedrm 1 in kit left of pantry door, 300.4 nail plates and 11/4" cables parallel, 300.14 short wires at boxes, 334.23 cables 6ft of attic access, 110.26(F)(2) remove low voltage from below p/s
Electrical Rough-In6/27/20086/30/20086/30/2008PFAIL
DetailsJack Frank
Basement and service inspection. Bob Johnston ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson corr box fill screws in plastic boxes, 14 AWG on 20 circuit, vacuum outlets, needs bushings for SER
Electrical Rough-In6/17/20086/17/20086/17/2008PPART
DetailsPat Lass
Rough inspection soffits. Please call Rick Sendra @ ###-#### Phone #: ###-#### Internet Inspection Request from: Kristopher Wilson
sofits ok