Final | 11/11/2008 | 11/12/2008 | 11/12/2008 | A | PASS |
Jack Frank
|
|
|
call for code # Phone #: ###-#### Internet Inspection Request from: Rick Beckman ok
|
Rough-In Permanent Service | 9/4/2008 | 9/5/2008 | 9/5/2008 | A | PASS |
Jack Frank
|
|
|
Rick Phone #: ###-#### Internet Inspection Request from: Rick Beckman r/i p/s u/g new ok
|
Rough-In Permanent Service | 9/3/2008 | 9/4/2008 | 9/4/2008 | A | FAIL |
Jack Frank
|
|
|
Rick Phone #: ###-#### Internet Inspection Request from: Rick Beckman all violations not meade , still needs 6" free length, and shall use required tool to crimp grd sleeves , loose splices called
|
Rough-In Permanent Service | 8/29/2008 | 9/2/2008 | 9/2/2008 | A | FAIL |
Jack Frank
|
|
|
optional # ###-#### Jeff Phone #: ###-#### Internet Inspection Request from: Rick Beckman corr called 300.4 nail plates and 11/4" for cables parallel, 314.16 box fill, 300.14 6" free length, 250.148 splice all equip grds together 210.52(C) required outlet countertop by pass through210.4(B) 2pole breakers foe multiwire branch circuits
|