Permit Information
Permit NumberELE08-02747
StatusFinaled
Name DAVID MORRISS
Site Address 1747 S WATERSILK PL
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Final12/2/200812/3/200812/3/2008APASS
DetailsBob Reichert
michelle Phone #: ###-#### met owner, corrections made ,ok to final
Final12/2/200812/2/200812/2/2008PNR
DetailsBob Reichert
michelle Phone #: ###-#### called corrections not done
Final12/1/200812/2/200812/2/2008PFAIL
DetailsBob Reichert
Michelle Phone #: ###-#### called, left correction notice, NEC 348.12(1) fmc shall not be used in wet locations and conductors must be suitable for wet locations, 210.52(D) shall install gfci protected receptacle within 3' of bath basin, 210.11(C)(3) there shall be no other outlets on bath circuit, 110.3(B) listed equipment shall be installed and used in accordance with labels and operate- garage entry area, 314.21 shall repair all drywall around boxes- less than 1/8" gap at u/c lights and range receptacle, 410.16(C) shall provide minimum 12" from edge of storage space to edge of fixture in clothes closet- master bed room, 680.73 tub access shall be per manufacturers instructions and accessible without removing screws or other permanent finish, 250.94 intersystem bonding terminination shall be provided
Conference12/1/200812/1/200812/1/2008PDONE
DetailsBob Reichert
michelle - conference - later afternoon please Phone #: ###-#### told owner if ready for final, needed to finish all work and call in for inspection
Electrical Rough-In10/29/200810/30/200810/30/2008PPASS
DetailsBob Reichert
bill Phone #: ###-#### ric ok
Permanent Service10/30/200810/30/200810/30/2008PPASS
DetailsBob Reichert
bill Phone #: ###-#### p/s u/g n ok
Electrical Rough-In10/22/200810/23/200810/23/2008ANR
DetailsBob Reichert
bill/david Note: please call 1/2 hr prior to inspection Phone #: ###-#### see conference
Conference10/23/200810/23/200810/23/2008ACANC
DetailsBob Reichert
bill/david Note: please call 1/2 hr prior to inspection Phone #: ###-#### called, left message, they asked for framer to take notes, reviewed grounding, outlet spacing, make-up, 1 1/4", stapling, all work to be installed, boxes flush with finished surface, abrasion protection, outlets placement front and back of building, access required for LB behind panel, suggested to wire without LB, 6" free conductor length, told only owner can wire building, circuiting for outside receptacles not to be on dining room circuit, and to be gfci protected. Called owner, told he could see on-line the items discussed.
Conference10/8/200810/9/200810/9/2008ADONE
DetailsBob Reichert
David ###-#### reviewed service, sub-panels, outlet spacing, no screws in boxes, 1 1/4", free length of conductor and when to call for ri