Final | 12/16/2008 | 12/16/2008 | 12/16/2008 | P | PASS |
Jack Frank
|
|
|
shawn Phone #: ###-#### ok
|
Permanent Service | 11/13/2008 | 11/13/2008 | 11/13/2008 | P | PASS |
Jack Frank
|
|
|
shawn Phone #: ###-#### at final need to check range and dryer for 4 wire recept and pigtals and hot and cold bonded p/s o/h rec. ok
|
Final | 11/12/2008 | 11/12/2008 | 11/12/2008 | P | FAIL |
Jack Frank
|
|
|
shawn Phone #: ###-#### met owner had conference needs conn for GEC , bond hot and cold with #4 copper, isolate grds and neutrals at subpanel, install raceway for conductors between p/s and subpanel or use SER, also needs mast straped and supported, and 4wire recepts and pigtails for range and dryer told owner to request a p/s inspection
|
Conference | 10/31/2008 | 10/31/2008 | 10/31/2008 | P | PART |
Pat Lass
|
|
|
Shawn Phone #: ###-#### talked about service change
|