Information based on query as of Friday, August 16, 2024.
Permit Information
Permit NumberELE08-02933
StatusVoid/No Violation
Name MICHAEL HOSKINS
Site Address 1705 N FRY ST
Project Name 
Customer Number 
ePlanReview 
Description
Contact Information
See Activities list for contact information
Show All Activities
DescriptionReceivedRequestedCompletedAM/PMDispositionAssigned To 
Electrical Rough-In8/4/20098/4/20098/4/2009PFAIL
DetailsBob Reichert
michael Phone #: ###-#### told owner he will have to get licensed electrical contractor to do further work, needs nail plates, 1 1/4" for wire, free length conductor, flush boxes with plywood wall covering, 20a circuits with wire size for laundry and bath, receptacle spacing, make-up, told owner that his permit will have to be voided
Electrical Rough-In7/21/20097/22/20097/22/2009ACANC
DetailsBob Reichert
###-#### wrong type request, see conference
Conference7/22/20097/22/20097/22/2009ADONE
DetailsBob Reichert
###-#### talked about make-up, 1 1/4", spacing receptacles, small appliance branch circuits, abandoned wiring, service clean-up, no esc this project
Permanent Service12/8/200812/8/200812/8/2008PCANC
DetailsBob Reichert
power co called about changes to passed p/s, went to inspect and owner made changes and created violations, told him he was supposed tp remove receptacle, close openings, not run nm cable in raceway, close lb fittings, close panel, strap conduit,etc. Told owner that he needs temp pole or to finish wiring before power can be reconnected.
Permanent Service12/3/200812/4/200812/4/2008PPASS
DetailsBob Reichert
mike Phone #: ###-#### p/s o/h rec ok
Electrical Rough-In11/19/200811/20/200811/20/2008AFAIL
DetailsJack Frank
mike Phone #: ###-#### met owner explained what is required for p/s , and r/i for 5 rms, and what circuits are required for kit ,laundry , din, liv. bed rm note owner needs to update permit for 5 rms and a p/s
Conference10/30/200810/31/200810/31/2008ADONE
DetailsBob Reichert
mike- call 1st before insp Phone #: ###-#### met owner talked about service upgrade , rewire of burned house, told owner that if he has electrician hepl him, that he would have to get permit, talked about grounding, mast, service drip loop too low