Final | 5/4/2009 | 5/4/2009 | 5/4/2009 | A | PASS |
Bob Reichert
|
|
|
For addition to back of residence. Thanks!!! Darryn Phone #: ###-#### Internet Inspection Request from: Darryn Coburn ok to final
|
Electrical Rough-In | 1/29/2009 | 1/29/2009 | 1/29/2009 | P | PASS |
Bob Reichert
|
|
|
darin Phone #: ###-#### corrections made, ric ok
|
Electrical Rough-In | 1/26/2009 | 1/26/2009 | 1/26/2009 | P | FAIL |
Bob Reichert
|
|
|
darrin Phone #: ###-#### called left message, left correction notice, NEC 300.4(A)&(D) edge of bored holes and nm cable shall be 1 1/4" from edge of framing members, 210.52(H) hallway over 10' in length shall have receptacle outlet, BCC all boxes shall be installed and made-up- baths and room adjoining existing house
|
Permanent Service | 1/7/2009 | 1/7/2009 | 1/7/2009 | P | PASS |
Bob Reichert
|
|
|
darrin - ###-#### p/s u/g n ok
|
Permanent Service | 1/6/2009 | 1/7/2009 | 1/7/2009 | P | CANC |
Bob Reichert
|
|
|
darrin Phone #: ###-#### see conference
|
Conference | 1/7/2009 | 1/7/2009 | 1/7/2009 | A | DONE |
Bob Reichert
|
|
|
darrin Phone #: ###-#### met electrician reviewed grounding and what must be done to change service from o/h to u/g
|