Final | 5/19/2009 | 5/20/2009 | 5/20/2009 | A | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 5/19/2009 at 11:46:28 AM. Contact: ###-####. ok
|
Rough-In Permanent Service | 3/23/2009 | 3/24/2009 | 3/24/2009 | P | PASS |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 3/23/2009 at 4:28:45 PM. Contact: ###-####. met contr. needs GEC too u/g water pipe within 5ft, p/s o/h rec. ok
|
Electrical Rough-In | 2/9/2009 | 2/11/2009 | 2/11/2009 | P | CANC |
Jack Frank
|
|
|
Scheduled by a contractor via Hello! on 2/9/2009 at 9:44:05 AM. Contact: ###-####. did inspection 02-10-09
|
Electrical Rough-In | 2/10/2009 | 2/10/2009 | 2/10/2009 | P | PART |
Jack Frank
|
|
|
Reinspection Phone #: ###-#### Internet Inspection Request from: Jari Rivers r/i ok called survey still needs some nail plates
|
Electrical Rough-In | 2/6/2009 | 2/9/2009 | 2/9/2009 | A | NH |
Jack Frank
|
|
|
reinspection, also need to add to permit 5 room, and 100amp service Phone #: ###-#### Internet Inspection Request from: Jari Rivers notice posted called
|
Electrical Rough-In | 2/5/2009 | 2/5/2009 | 2/5/2009 | P | FAIL |
Jack Frank
|
|
|
Cover inspection, If possible to be done early, owner will not be available late afternoon Phone #: ###-#### Internet Inspection Request from: Jari Rivers corr . called box fill nail plates and 11/4", grd wires cut short needs 6", outlet for wall space island counter, grd metal boxes, update permit for # of rms and p/s
|